Mathematical Problems in Engineering
Volume 2010 (2010), Article ID 121757, 21 pages
doi:10.1155/2010/121757
Research Article

Pulsatile Flow of Two-Fluid Nonlinear Models for Blood Flow through Catheterized Arteries: A Comparative Study

1School of Mathematical Sciences, Science University of Malaysia, Penang 11800, Malaysia
2Department of Mechanical Engineering, Inha University, 253 Yonghyun-Dong, Nam-Gu, Incheon 402-751, South Korea

Received 3 September 2009; Revised 7 December 2009; Accepted 21 January 2010

Academic Editor: Ekaterina Pavlovskaia

Copyright © 2010 D. S. Sankar and Usik Lee. This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.

Abstract

The pulsatile flow of blood through catheterized arteries is analyzed by treating the blood as a two-fluid model with the suspension of all the erythrocytes in the core region as a non-Newtonian fluid and the plasma in the peripheral layer as a Newtonian fluid. The non-Newtonian fluid in the core region of the artery is represented by (i) Casson fluid and (ii) Herschel-Bulkley fluid. The expressions for the flow quantities obtained by Sankar (2008) for the two-fluid Casson model and Sankar and Lee (2008) for the two-fluid Herschel-Bulkley model are used to get the data for comparison. It is noted that the plug-flow velocity, velocity distribution, and flow rate of the two-fluid H-B model are considerably higher than those of the two-fluid Casson model for a given set of values of the parameters. Further, it is found that the wall shear stress and longitudinal impedance are significantly lower for the two-fluid H-B model than those of the two-fluid Casson model.